Reclosed MCCB with Leakage protection

Availability:

100 in stock


MTM5-EL is an integrated system of smart meter, breakers, communications.

Electrical parameter monitoring
Full Protection
Prepaid metering function with AMR
Billing system and online payment
Bidirectional Communications
Remote control and remote lock
Tamper event detection, recording and reporting
Power event alarms
Current is up to 630A

Rp4,500,000

100 in stock

Compare

MTM5-EL is an integrated system of smart meter, breakers, communications.

Electrical parameter monitoring
Full Protection
Prepaid metering function with AMR
Billing system and online payment
Bidirectional Communications
Remote control and remote lock
Tamper event detection, recording and reporting
Power event alarms
Current is up to 630A

Technical specification
Item Code: MTS3-EL125 MTS3-EL250 MTS3-EL400 MTS3-EL630
Standards: IEC60947-2, IEC61009
Approvals: CE,CCC,
Poles 3P+N
Frame Current A 125 250 400 630
Rated Current A 40,50,63,80,100,125 100, 125, 140, 160 ,180, 200, 225, 250 200, 225, 250, 315, 350, 400 400,500,630
Rated Voltage Vac 400
Insulation Voltage Vac 800
Frequency (HZ): Hz 50/60
Rated impulsed withstand
voltage, Uimp Vac 8000
Acing distance mm >50 >100
Rated ultimate short-circuit
breaking capacity, Icu kA 50 65
Rated operating short-circuit
breaking capacity, Ics kA 35 42
Rated residual making and
breaking capacity (I∆m) kA 12.5 20
Type (wave form of the earth
leakage sensed) AC
Rated residual current (I∆n) mA 50,100,200,400,600,800 , AUTO, OFF 100,200,300,500,800,1000 ,auto, OFF
Breaking time under I∆n for Delay type s 0.06/0.1/0.2 for option, 2 I∆n
Breaking time s I∆n<=0.5,2 I∆n<=0.2;52 I∆n<=0.15
Auto-recloser time s 20-60
Over voltage protection value Vac 250-300(+/-5%)
Under voltage protection value Vac 150-200(+/-5%)
Remote control delay time ms <=40ms
Communication delay time ms <=200ms
Protections Overload, Short-Circuit, Earth Leakage, Auto-reclose,Phase Loss, Over voltage and Under voltage
Monitoring of electrical circuit parameter Current, Voltage,Power, Temperature,Frequecy, Power factor
Parameter value setting Rated residual current value, Long-delay time for overload,Short-delay time for Short circuit, Instantaneous time for Short Circuit,Over votlage protection value, and Under voltage protecdtion value.
Electric Life Times 1500 1000 1000 1000
Mechanical Life Times 8500 7000 4000 4000
Connectivity RS485, infrared and Added-on communication of WIFI, TCP, GPS,NB-IoT, LoRa, Zigbee RS485, infared, WIFI, TCP integrated inside. Added-on communication of WIFI, TCP, GPS,NB-IoT, LoRa, Zigbee RS485, infrared and Added-on communication of WIFI, TCP, GPS,NB-IoT, LoRa, Zigbee
Software App and software platform for option
Communication Protocal TCP, Modbus
Pollution Degree 2
Ambient temperature: °C -55 – +40
Storage temperature: °C -25—+70
Humidity < 50%
Altitude: m <=2000
Connection From top to bottom

Weight1 kg

Technical specification
Item Code: MTS3-EL125 MTS3-EL250 MTS3-EL400 MTS3-EL630
Standards: IEC60947-2, IEC61009
Approvals: CE,CCC,
Poles 3P+N
Frame Current A 125 250 400 630
Rated Current A 40,50,63,80,100,125 100, 125, 140, 160 ,180, 200, 225, 250 200, 225, 250, 315, 350, 400 400,500,630
Rated Voltage Vac 400
Insulation Voltage Vac 800
Frequency (HZ): Hz 50/60
Rated impulsed withstand
voltage, Uimp Vac 8000
Acing distance mm >50 >100
Rated ultimate short-circuit
breaking capacity, Icu kA 50 65
Rated operating short-circuit
breaking capacity, Ics kA 35 42
Rated residual making and
breaking capacity (I∆m) kA 12.5 20
Type (wave form of the earth
leakage sensed) AC
Rated residual current (I∆n) mA 50,100,200,400,600,800 , AUTO, OFF 100,200,300,500,800,1000 ,auto, OFF
Breaking time under I∆n for Delay type s 0.06/0.1/0.2 for option, 2 I∆n
Breaking time s I∆n<=0.5,2 I∆n<=0.2;52 I∆n<=0.15
Auto-recloser time s 20-60
Over voltage protection value Vac 250-300(+/-5%)
Under voltage protection value Vac 150-200(+/-5%)
Remote control delay time ms <=40ms
Communication delay time ms <=200ms
Protections Overload, Short-Circuit, Earth Leakage, Auto-reclose,Phase Loss, Over voltage and Under voltage
Monitoring of electrical circuit parameter Current, Voltage,Power, Temperature,Frequecy, Power factor
Parameter value setting Rated residual current value, Long-delay time for overload,Short-delay time for Short circuit, Instantaneous time for Short Circuit,Over votlage protection value, and Under voltage protecdtion value.
Electric Life Times 1500 1000 1000 1000
Mechanical Life Times 8500 7000 4000 4000
Connectivity RS485, infrared and Added-on communication of WIFI, TCP, GPS,NB-IoT, LoRa, Zigbee RS485, infared, WIFI, TCP integrated inside. Added-on communication of WIFI, TCP, GPS,NB-IoT, LoRa, Zigbee RS485, infrared and Added-on communication of WIFI, TCP, GPS,NB-IoT, LoRa, Zigbee
Software App and software platform for option
Communication Protocal TCP, Modbus
Pollution Degree 2
Ambient temperature: °C -55 – +40
Storage temperature: °C -25—+70
Humidity < 50%
Altitude: m <=2000
Connection From top to bottom

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Reclosed MCCB with Leakage protection”

This site uses Akismet to reduce spam. Learn how your comment data is processed.

There are no reviews yet.