-4%

B Type RCCB

Availability:

100 in stock


ML60-B B type RCCB can detect high frequency AC and smooth DC earth residual currents. It is also named as “universal current sensitive RCCB”, which means it could be used for the widest variety of applications like variable speed drives, PV system, EV charging station and there are always also designed for use under harsh ambient.

Rp2,498,000 Rp2,600,000

100 in stock

Compare

ML60-B B type RCCB can detect high frequency AC and smooth DC earth residual currents. It is also named as “universal current sensitive RCCB”, which means it could be used for the widest variety of applications like variable speed drives, PV system, EV charging station and there are always also designed for use under harsh ambient.

Spesification :
Electrical Features
Standard: IEC/EN62423 & IEC/EN 61008-1
Type (wave form of the earth leakage sensed): Type B
Poles: 1P+N, 3P+N
Rated Current(In): 25,40,63A
Rated Sensitivity I&n: 30mA, 100mA, 300mA
Insulation Voltage Ui: 500V
Rated Residual Making and Breaking Capacity I&m: 500A (In=25/40A0), 630A (In=63A
Short-Circuit Current Inc=I&c : 10000A
SCPD Fuse :10000A
Break Time under I&n :<=0.1A
Rated Frequency :50 Hz
Rated Impulse Withstand Voltage (1.2/5.0) Uimp: 4000V
Dielectric Test Voltage at ind.Freq.for 1min :2.5 kV
Pollution Degree: 2
Mechanical Features
Electrical Life: 2000 times
Mechanical life: 10000 times
Fault Current Indicator: Yes
Protection Degree: IP20
Ambient Temperature (with daily averages<=35 C): -25-40 C
Storage Temperation : -25- 70C
Installation Features
Terminal Connection Type: Cable/ U-Type Busbar
Terminal Size Top/Bottom for cable: 25/35 mm 18-3/18-2 AWG
Terminal Size top/bottom for Busbar: 10/16 mm2 18-8/18-5AWG
Tightening Torque : 2.5 N.M
Connection : From top to Bottom
Mounting: On DIN Rail EN60715(35mm)

SKU: ML60-B Category: Tag:
Weight1 kg

Spesification :
Electrical Features
Standard: IEC/EN62423 & IEC/EN 61008-1
Type (wave form of the earth leakage sensed): Type B
Poles: 1P+N, 3P+N
Rated Current(In): 25,40,63A
Rated Sensitivity I&n: 30mA, 100mA, 300mA
Insulation Voltage Ui: 500V
Rated Residual Making and Breaking Capacity I&m: 500A (In=25/40A0), 630A (In=63A
Short-Circuit Current Inc=I&c : 10000A
SCPD Fuse :10000A
Break Time under I&n :<=0.1A
Rated Frequency :50 Hz
Rated Impulse Withstand Voltage (1.2/5.0) Uimp: 4000V
Dielectric Test Voltage at ind.Freq.for 1min :2.5 kV
Pollution Degree: 2
Mechanical Features
Electrical Life: 2000 times
Mechanical life: 10000 times
Fault Current Indicator: Yes
Protection Degree: IP20
Ambient Temperature (with daily averages<=35 C): -25-40 C
Storage Temperation : -25- 70C
Installation Features
Terminal Connection Type: Cable/ U-Type Busbar
Terminal Size Top/Bottom for cable: 25/35 mm 18-3/18-2 AWG
Terminal Size top/bottom for Busbar: 10/16 mm2 18-8/18-5AWG
Tightening Torque : 2.5 N.M
Connection : From top to Bottom
Mounting: On DIN Rail EN60715(35mm)